IEC 60068-2-6, IEC 60068-2-27 and IEC 60068-2-64 tell a test laboratory how to run a vibration or shock test. They do not tell you which severity matches your product, whether the test runs on the bare pack or the assembled device, or what result counts as a pass. Those decisions belong to the equipment maker, and they are exactly what turns a generic test report into a qualification result you can act on. A report that says “tested to IEC 60068-2-6” is not an acceptance statement until the levels, the test configuration and the pass criteria are written down.
This article maps the four mechanical tests that matter for battery packs, separates the three decisions – method, severity and acceptance criteria – and provides a checklist for writing criteria a pack supplier can be held to.

The four mechanical tests that matter for packs
Four test types cover most mechanical qualification needs for a custom battery pack, and each stresses a different failure mechanism.
- Sinusoidal vibration – IEC 60068-2-6 (Test Fc) sweeps a sinusoidal excitation across a frequency range and dwells at defined points. It is the tool for finding resonances and for equipment that lives near rotating machinery, where the excitation is genuinely periodic.
- Random vibration – IEC 60068-2-64 (Test Fh) applies a broadband random profile. It resembles road transport and mixed service environments better than any swept sine does, and it accumulates fatigue across a band of frequencies at once.
- Mechanical shock – IEC 60068-2-27 (Test Ea) applies short-duration impact pulses. It represents handling bumps, braking events and door slams, and it tends to expose loose fasteners, marginal welds and connector retention problems that slow vibration misses.
- Drop and free fall – drop robustness is usually defined within the product specification for hand-held and portable equipment. Transport safety is handled separately: the UN 38.3 transport test series includes its own vibration and shock tests, whose purpose is to prove the pack can survive shipping, not years in service.
| Test | Standard | What it stresses | Typical purpose |
|---|---|---|---|
| Sinusoidal vibration | IEC 60068-2-6 (Test Fc) | Resonances; fatigue at specific frequencies | Equipment mounted near rotating machinery |
| Random vibration | IEC 60068-2-64 (Test Fh) | Broadband fatigue accumulation | Transport and mixed service environments |
| Mechanical shock | IEC 60068-2-27 (Test Ea) | Short-duration impact response | Handling bumps, braking, door closures |
| Drop / free fall | Product specification; UN 38.3 for transport safety | Accidental drops | Hand-held and portable equipment |
Method, severity and acceptance are three separate decisions
Much of the confusion around mechanical qualification comes from collapsing three different decisions into one line in a datasheet.
Method is which test you run, and the IEC 60068-2 parts define the procedure. Severity is the numbers – frequency ranges, amplitudes, durations, shock pulse shapes and heights – and the standards offer menus of severities rather than prescribing one, expecting the product specification to select them. Acceptance criteria are what you will measure afterwards and what values count as a pass. The standards never define those limits; they are yours.
A practical consequence: two packs “tested to IEC 60068-2-6” can have been exposed to completely different levels, run in different fixtures and judged against different criteria. Writing all three decisions into the pack specification is what makes the test report reviewable.
| Service environment | Suggested emphasis | Why |
|---|---|---|
| Mounted near motors, fans or pumps | Sinusoidal sweep, then dwell at the excitation frequencies | Periodic forcing is dominant in service |
| Vehicle-mounted or shipped equipment | Random vibration profile | Road and transport input is broadband |
| Hand-held or portable device | Shock and drop, plus sinusoidal screening | Handling and impact dominate the duty profile |
| Fixed ESS cabinets | Mild sinusoidal screening; transport robustness handled by packaging qualification | Service excitation is low; shipping is the stressed phase |
This table is an orientation aid, not a severity selection – confirm the levels against the actual mounting location and transport profile of the device.
Axes, durations and test sequence belong in the specification too
Beyond method and severity, three practical details decide whether a test report from two suppliers describes the same programme. The first is the axis set: vibration tests are normally run on three orthogonal axes, and the specification should say whether the pack is tested in all three, in which orientation relative to its cell stack, and whether intermediate electrical measurements are taken between axes. The second is the exposure quantity: durations or cycle counts per axis for vibration, the number of shock pulses per direction, and the drop heights and orientations for free fall. The third is the sequence, because mechanical damage accumulates. Shock before vibration and vibration before shock are different tests on the same hardware, and mixing a used sample into a second test muddies the result. State the order, state whether each test uses a fresh sample, and record that the samples are sacrificial – a qualification pack should never re-enter production stock.
These details are not bureaucratic. They are what allows a supplier’s in-house result to be compared against a third-party laboratory’s result, and what allows an auditor to reconstruct the programme two years later from the report alone.
Writing acceptance criteria a report can be judged against
The most useful structure is a before-and-after comparison: measure the pack in a defined state before the mechanical test, repeat the same measurements after, and judge the change. The table below shows the checks worth including. The example values are illustrative only and must be set from the device requirement – none of them comes from a standard.
| Check | Method | Example criterion (set to your requirement) | Typical disposition on failure |
|---|---|---|---|
| Safety events | Visual and functional check after each axis or sequence | No leakage, venting, rupture or fire | Reject – safety-critical, no retest |
| Electrical continuity | Open-circuit voltage and resistance measured before and after | Open-circuit voltage change within a defined band | Investigate; isolate the affected sample |
| Capacity retention | Reference-condition discharge before and after | Retention within a defined percentage of the pre-test value | One retest permitted; scrap on repeat |
| Insulation resistance | Insulation tester at a defined voltage | Above a defined threshold | Reject |
| BMS function | Full self-check and fault log read-back | No new fault codes; protection trips verified | Investigate firmware and hardware separately |
| Mechanical integrity | Visual inspection; torque check on fixings | No cracks, loosened fasteners or displaced interconnects | Containment review before retest |
Two points make this table work in practice. First, every row needs the measurement conditions attached – temperature, state of charge, rest time – because capacity and resistance readings move with both. Second, the electrical rows should use the same measurement procedure as your routine incoming inspection, so results from qualification and production are comparable.
Each criterion must also be checkable by someone other than the person who wrote it. “No visible damage” is enforceable only if the specification states the lighting, the inspection distance and what counts as a crack versus a mark. “BMS function normal” is enforceable only if the specification names which self-check runs and how the fault log is read back. A criterion that names its instrument, its conditions and its tolerance can be applied identically by your own lab and by the supplier’s – which is the whole point of writing it down.
Bare pack or assembled device: define the test boundary
The same pack can pass a vibration test in a stiff fixture and fail when it is installed in a device whose housing amplifies the excitation. Fixture stiffness, mounting orientation, and whether the connector is mated or capped all change what the pack actually experiences. The specification should therefore state the test configuration explicitly: bare pack in a defined fixture, or installed in the device; which axes; which orientations for drop; whether the BMS stays powered and connected to a host simulator. A pack whose BMS is unpowered during the test cannot record what happened to it, so the powered-and-connected configuration usually yields a richer result – provided the fault-log read-back is part of the acceptance criteria.
The mechanical test also has an environmental companion. Temperature cycling, humidity and ingress protection sit alongside the mechanical programme in a full qualification plan – our article on battery pack enclosure design covers how the enclosure choices made at design time determine which of those environmental tests the pack can realistically pass.

How this differs from UN 38.3 transport testing
UN 38.3 is a transport-safety gate. Its vibration and shock tests exist to show that a pack can be shipped without creating a hazard, and that is what passing them proves. It does not show that the pack survives five years of duty cycles on a mobile robot or a medical cart. Product qualification under IEC 60068 methods answers the service-life question, and the two programmes overlap only partially.
The practical rule: if your device ships by air or sea, UN 38.3 compliance is a legal prerequisite for transport – the IATA lithium battery guidance summarises the transport requirements – while the IEC 60068-based qualification described here protects your product in the field. Our overview of the UN 38.3 test covers the transport side in detail.
For portable products, the finished pack will also be certified against IEC 62133-2, whose abuse-type tests complement the mechanical qualification programme rather than replace it.