Handling of battery
Prohibitionshort circuit
Never short circuit battery. It generates very high current which causes heating of the battery and may cause electrolyte leakage, gassing or explosion that is very dangerous.
The poles may be easily short-circuited by putting them on conductive surface. Such outer short circuit may lead to heat generation and damage of the battery.
An appropriate circuitry with PCM shall be employed to protect accidental short circuit of the battery pack.
Mechanical shock
Falling, hitting, bending, etc. may cause degradation of battery characteristics.
MODEL:INM18.5-26E2 (18.5V2.6AH)
Prepared By/Date | Checked By/Date
| Approved By/Date
|
Customer Approval | Signature/Date |
Company Name | |
Company Stamp | |
Amendment Records | ||||
Edition | Description
| Prepared by
| Approved by
| Date
|
A0 | First Edition | nancy | ||
This specification is applied to the LiNiCoMnO2 battery pack manufactured by Shenzhen Huarui Xinchuang Technology Co.,Ltd
Table 1
No.
| Item
| General Parameter
| Remark
|
1 | Rated Capacity
| 2.6Ah | Standard discharge(0.5 C5) after standard charge(0.5 C5)
|
2 | Minimal Rated Capacity
| 2.5Ah | |
3 | Nominal Voltage | 18.5V | |
4 |
Cycle Life |
Higher than 60% of the Initial Capacity of the Cells | 2. Charge: CC@0.5C to 21V, then CV till current to 0.05C 3. Rest: 30min. 4. Discharge: 0.5C to 15V 5. Temperature:20±5℃ 6. Carry out 500cycles
|
5 | Discharge cut-off voltage | 15V | 15V is recommended |
6 | Charging cut-off voltage | 21V | |
7 | Cell and assembly method
| INR18650EC-2600mAh cell | 5S1P |
8 | Housing material | PVC | Blue |
Continuous the table 1 | |||||
No.
| Item
| General Parameter | Remark | ||
9 |
Standard charge | 0.5C constant current(CC) charge to 21V,then constant voltage (CC)21V charge till charge current decline to ≤0.05C |
Charge time : Approx 4h | ||
10 | Standard discharge
| Constant current 0.5C Cut-off voltage 15V
| |||
11 | Maximum Charge Current | 3A | |||
12 | Continuous Discharge Current
|
5A | |||
13 | Operation Temperature Range | Charge: 0~45℃ |
60±25%R.H. | ||
Discharge: -20~60℃ | |||||
14 |
Storage Temperature Range
| Less than 1 year : 0~25℃ |
60±25%R.H. at the shipment state | ||
Less than 3 months:-5~35℃ | |||||
15 | Weight | Approx: 300g | |||
16 |
Max. Dimensions
| Length: 92mm | |||
Width: 70mm | |||||
Thickness: 20mm |
Test should be conducted with new batteries within one week after shipment from our factory and the batteries shall not be cycled more than five times before the test. Unless otherwise specified, test and measurement shall be done under temperature of 20±5℃ and relative humidity of 45~85%. If it is judged that the test results are not affected by such conditions, the tests may be conducted at temperature 15~30℃ and humidity 25~85%RH.
The dimension measurement shall be implemented by instruments with equal or more precision scale of 0.01mm.
Standard class specified in the national standard or more sensitive class having inner impedance more than 10kΩ/V
Standard class specified in the national standard or more sensitive class. Total external resistance including ammeter and wire is less than 0.01Ω.
Impedance shall be measured by a sinusoidal alternating current method (1kHz LCR meter).
Charging shall consist of charging at a 0.5C constant current rate until the battery reaches 21V. The battery shall then be charged at constant voltage of 21V volts while tapering the charge current. Charging shall be terminated when the charging current has tapered to 0.05 C5A. Charge time: Approx 4h, The battery shall demonstrate no permanent degradation when charged between 0 ºC and 45 ºC.
Battery shall be discharged at a constant current of 0.5C to 15V @ 20º ± 5C
There shall be no such defect as crack, rust, leakage, which may adversely affect commercial value of battery.
Never short circuit battery. It generates very high current which causes heating of the battery and may cause electrolyte leakage, gassing or explosion that is very dangerous.
The poles may be easily short-circuited by putting them on conductive surface. Such outer short circuit may lead to heat generation and damage of the battery.
An appropriate circuitry with PCM shall be employed to protect accidental short circuit of the battery pack.
4.2.Mechanical shock
Falling, hitting, bending, etc. may cause degradation of battery characteristics.
Prevention of short circuit within a battery pack
Enough insulation layers between wiring and the cells shall be used to maintain extra safety protection. The battery pack shall be structured with no short circuit internally, which may cause generation of smoke or firing.
The period of warranty is 12 months from the date of shipment. Huarui Xinchuang guarantees to give a replacement in case of battery with defects proven due to manufacturing process instead of the customer abuse and misuse.
The batteries should be stored at room temperature, charged to about 30% to 50% of capacity. We recommend that batteries be charged about once per three months to prevent over-discharge.
Because batteries utilize a chemical reaction, battery performance will deteriorate over time even if stored for a long period of time without being used. In addition, if the various usage conditions such as charge, discharge, ambient temperature, etc. are not maintained within the specified ranges the life expectancy of the battery may be shortened or the device in which the battery is used may be damaged by electrolyte leakage. If the batteries cannot maintain a charge for long periods of time, even when they are charged correctly, this may indicate it is time to change the battery.
Wiring: AWG 22#, 180±5mm; with connector-TYCO280359/280708-2, (1-P+,2-NTC-10k, 3-NTC-10k, 4-P-)
Item | Content | Criterion |
Voltage | Charging voltage | DC:21V CC/CV |
Balance voltage for single cell | 4.20±0.025V | |
Current | Balance current for single cell | 42±10mA |
Low Current consumption | ≤50uA | |
Max continues charge current | 5A | |
Max continues discharge current | 5A | |
Over charge Protection
| Over charge detection voltage | 4.25±0.025V |
Over charge detection delay time | ≤1.5S | |
Over charge release voltage | 4.10±0.05V | |
Over discharge protection
| Over discharge detection voltage | 2.8±0.08V |
Over discharge detection delay time | ≤150mS | |
Over discharge release voltage | 3.0±0.10V | |
Over current protection
| Over current detection voltage | 0.10±0.015V |
Over current detection current | 20±2A | |
Detection delay time | ≤20mS | |
Short protection | Detection delay time | ≤540uS |
Detection condition | 3.Exterior short circuit &10AH/10C&25℃ | |
Release condition | Cut short circuit | |
Interior resistance | Main loop electrify resistance | ≤50mΩ |
Operating temperature | Operating temperature range | -40~+85℃ |
Storage temperature | Storage temperature range | -40~+125℃ |
3(T)*12(W)*85(L)