3.3.2 Standard Discharge : 0.2C Battery shall be discharged at a constant current of 0.2C to10.0V @ 20º ± 5C 3.3.3 If no otherwise specified, the rest time between charging and discharging is 30min. 3.4 Appearance There shall be no such defect as crack, rust, leakage, which may adversely affect commercial value of battery. 4. Handling of battery 4.1 Prohibition short circuit Never short circuit battery. It generates very high current which causes heating of the battery and may cause electrolyte leakage, gassing or explosion that is very dangerous. The poles may be easily short-circuited by putting them on conductive surface. Such outer short circuit may lead to heat generation and damage of the battery. An appropriate circuitry with PCM shall be employed to protect accidental short circuit of the battery pack. 4.2.Mechanical shock Falling, hitting, bending, etc. may cause degradation of battery characteristics. 5. Period of Warranty The period of warranty is18months from the date of shipment. Huarui Xinchuang guarantees to give a replacement in case of battery with defects proven due to manufacturing process instead of the customer abuse and misuse. 6. Storing the Batteries The batteries should be stored at room temperature, charged to about 30% to 50% of capacity.We recommend that batteries be charged about once per three months to prevent over-discharge. |